MPPT Solar Charge Controller 12~48V
MPPT Solar Charger Controller ,12V 24V 36V 48V. Works with Lead acid and Lithium batteries. Varients for 30A, 40A, 50A, and 60A.
Features:
- Built-in DSP controller with high performance
- Automatic battery voltage detection 12V/24V/36V/48V
- Three-stage charging optimized for battery performance
- Multi-function LCD displays
- Reverse polarity protection of solar panel
- Overcharge protection
- Easy installation
- Suitable for both Lead Acid and Lithium battery types
Brand Name: PowMr
Certification: CE
Model Number: MPPT 60A 50A 40A 30A
Charging mode: MPPT Maximum power point tracking automatically
Dispaly: Backlight LCD Controller
Battery Voltage: 12V 24V 36V 48V Auto
Battery Type: Lead Acid/Vented/ Sealed / Gel / NiCd /AGM/ Lithium battery
Product Specifications:
Model Name | MPPT-30A | MPPT-40A | MPPT-50A | MPPT-60A |
Charging mode | MPPT Maximum power point tracking automatically | |||
Charging | 3-stage:constant current(MPPT), constant voltage(Absorption Voltage), floating charge | |||
System type | DC12V/24V/36V/48V Recognition automatically | |||
System voltage automatic recognition | 12V system (DC9V-DC15V) | |||
24V system (DC18V-DC29V) | ||||
36V system (DC30V-DC39V) | ||||
48V system (DC40V~DC60V) | ||||
Soft start time | ≤1S | |||
Dynamic response and recovery time | ≥98.1% (Voc is 1.5 or 2 times than battery, then it’s best efficiency) | |||
PV utilization | ≥99% | |||
Input specification | ||||
Voc from PV( Make sure the Voc of PVmeeting the requirement as right. Voc is 1.5 or 2 times than battery, then it’s best efficiency. ) |
12V system (DC20V~DC80V) | |||
24V system (DC37V~DC105V) | ||||
36V system (DC50V~DC160V) | ||||
48V system (DC72V~DC160V) | ||||
The maximum PV input voltage (Voc) | DC190V(The controller can’t work at this voltage of long duration that will break controller. Please refer to Input voltage from PV.) | |||
The maximum PV input power(The total power rated of PV can’t be over this watt that will break the controller.) |
12V system (360W) | 12V system (480W) | 12V system (600W) | 12V system (720W) |
24V system (720W) |
24V system (960W) |
24V system (1200W) | 24V system (1440W) | |
36V system (1080W) | 36V system (1400W) | 36V system (1800W) | 36V system (2100W) | |
48V system (1440W) | 48V system (1700W) | 48V system (2200W) | 48V system (2800W) | |
Output specification | ||||
Selectable battery type(default is Sealed) | Vented/ Sealed / Gel / NiCd / Lithium battery(defined voltage for other battery by user) | |||
Absorption Charging Voltage | Refer to Batteries charging reference | |||
Floating Charging Voltage | Refer to Batteries charging reference | |||
Overcharging protection voltage | 12V system (15V) | |||
24V system (30V) | ||||
36V system (45V) | ||||
48V system (60V) | ||||
Rated output current |
30A | 40A | 50A | 60A |
Temperature Coefficient | ±0.02%/ centi-degree | |||
utomatic temperature compensation | 14.2V-(Max temperature-25 centi-degree)*0.3 | |||
Output voltage ripple-peak | 100mV | |||
Output voltage accurac | ≤±1% | |||
Input Anti-intrusion protection | yes | |||
Temperature Protection | 75°C | |||
Temperature increased protection |
Output power will reduce when it’s more 70 °C Output power will be normal when it’s less 55 °C |
|||
Fan-on temperature | >40 °C | |||
Fan-off temperature | <35 °C | |||
Acoustic noise | ≤40dB | |||
Cooling way | Forced air cooling | |||
Components | Imported materials, Accord to EU standards, Industrial grade range. | |||
Environmental requirements | Meet 2002/95/EC; No cadmium, hydrides and fluorides | |||
Security Level | Accord to CE, PSE, FCC, EMC, EN60950 | |||
Electromagnetic Compatibility | Accord to EN61000, EN55022, EN55024 | |||
Enclosure | IP21 | |||
Net weight(Kg) | 1.1 | |||
Gross weight(Kg) | 1.2 |
Cooling way: Forced air cooling
Voc from PV (12V battery): DC20V~DC80V
Voc from PV (24V battery): DC37V~DC105V
Voc from PV (36V battery): DC50V~DC160V